Call us now +1-613-484-2847







Product Details


Details



Addressable Control Panel

Product Type : Fire Alarm
Product Category : Addressable Control Fire Alarm System
Product Model : SME-WMP2-EN
Product Status : Non Discontinued


Downloads



Product Features

Product Specifications

Operating voltage AC (85 ~ 260) V / 50/60 Hz
Mains supply current limit 1.5 A / AC 230 V
Mains supply fuse 4 A / AC 250 V slow blow (20 mm)
Mains supply fault threshold voltage ≤ AC 60 V
Power supply 2.2 A / DC 28 V
Standby battery capacity (2 × DC 12 V) 7.2 Ah
Maximum battery current draw 1.5 A / maximum operating temperature
Battery fuse 6 A resettable (electronic fuse)
Battery fault threshold voltage < DC 20 V
Quiescent current 110 mA / 28.5 V
Addressable loops 2
Number of connected devices per loop 125
Loop current (max) 400 mA
Loop monitoring Open- and short-circuit
Configurable audio/visual alarm groups (max) 512
Conventional audio/visual alarm device driver 800 mA
Conventional audio/visual alarm end-offline resistor 10 kΩ
Alarm zone monitoring Open- and short-circuit
Alarm zone voltage (max) DC 27.5 V
Alarm zone fuse 1.1 A resettable (electronic fuse)
Number of programmable output relays 2
Ancillary fire C/O relay 2 x (1.0 A / DC 30 V / 1 A / AC 240 V)
Ancillary fault N/C relay 1.0 A / DC 30 V / 1 A / AC 240 V
Auxiliary supply DC 28 V / 300 mA
Evacuation start / stop input Non-latching, voltage-free
Remote reset input Non-latching, voltage-free
Number of networked panels 4
Terminal wiring (0.4 ~ 2.5) mm2
Operating temperature (-5 ~ +40) °C
Operating humidity (0 ~ 95) % RH, non-condensing
Storage temperature (-25 ~ +80) °C
Storage humidity (0 ~ 98) % RH, non-condensing
Dimensions (h × w × d) (420 × 337 × 99) mm
Weight (excluding batteries) 4.0 kg

Releasing Outputs

Pre-release delay time (0 ~ 30) s in 5 s intervals
Number of programmable output relays 6
Stage One contact rating 1.0 A / DC 30 V / 0.5 A / AC 125 V
Stage Two output Continuous or pulsing / 1 s on / 1 s off
Stage Two contact rating 1.0 A / DC 30 V / 0.5 A / AC 125 V
Extinguishment release time (60 ~ 300) s in 5 s intervals or until Reset
Extinguishment output 2 delay time (0 ~ 10) min in 1 min intervals
Extinguishant released indication Immediate upon release or pressure switch input signal
Released contact rating 1.0 A / DC 30 V / 0.5 A / AC 125 V
Aborted contact rating 1.0 A / DC 30 V / 0.5 A / AC 125 V
Reset inhibit time (0 ~ 30) min in 1 min intervals
Extraction fan contact rating 1.0 A / DC 30 V / 0.5 A / AC 125 V
Earth fault monitoring Enabled / Disabled
Fault output Enabled / Disabled
Fault relay contact rating 1.0 A / DC 30 V / 0.5 A / AC 125 V
Auxiliary supply output (continuous) DC 30 V (max) / 200 mA

Audio/Visual Alarms

Conventional audio/visual alarm device output 1000 mA
total Conventional audio/visual alarm endof- line resistor 10 kΩ
Alarm zone voltage (max) DC 30 V
Electronic alarm zone fuse 1 A

Miscellaneous

Number of user interface languages 2
Terminal wiring (0.4 ~ 2.5) mm2
Operating temperature (-5 ~ +40) °C
Operating humidity (0 ~ 95) % RH, non-condensing
Storage temperature (-25 ~ +80) °C
Storage humidity (0 ~ 98) % RH, non-condensing
Dimensions (h × w × d) (400 × 330 × 85) mm
Weight (excluding batteries) 4.3 kg